Welcome! This guide provides essential information for installing, operating, and maintaining your Ideal Isar HE24 boiler, ensuring efficient and safe heating․

Overview of the Isar HE24 Boiler

The Ideal Isar HE24 is a highly efficient, wall-mounted condensing boiler designed for central heating and domestic hot water․ It’s known for its compact size, making it suitable for various installation locations within a home․ This boiler utilizes advanced combustion technology to maximize fuel efficiency and minimize emissions, contributing to lower heating bills and a reduced carbon footprint․

The HE24 model specifically offers a heating output of 24kW, making it appropriate for medium-sized homes with a moderate demand for heating and hot water․ It features a user-friendly control panel for easy operation and adjustment of settings․ Regular servicing, as outlined in this guide, is crucial for maintaining optimal performance and longevity; Understanding its features will ensure reliable and cost-effective operation․

Key Features and Benefits

The Ideal Isar HE24 boasts several key features, including a high-efficiency condensing design, resulting in lower gas consumption and reduced energy costs․ Its compact dimensions facilitate installation in various spaces, even those with limited room․ The boiler’s modulating output automatically adjusts to heating demands, optimizing performance and comfort․

Benefits include reliable central heating and hot water supply, a user-friendly interface for simple operation, and reduced environmental impact due to lower emissions․ The HE24 also incorporates safety features like dry fire lockout and frost protection․ Furthermore, readily available parts and a comprehensive support network ensure ease of maintenance and servicing, maximizing its lifespan and providing peace of mind․

Installation Procedures

Caution! Proper installation by a qualified engineer is crucial for safe and efficient operation of the Ideal Isar HE24 boiler system․

Pre-Installation Checks

Before commencing installation, several critical checks must be performed to ensure compatibility and safe operation․ Verify the gas supply pressure aligns with the boiler’s requirements, detailed in the technical specifications․ Confirm adequate ventilation is present in the installation location, adhering to current building regulations․

Inspect the flue route for obstructions and ensure it meets the specified dimensions and material guidelines․ Assess the structural integrity of the wall or floor intended to support the boiler’s weight․

Check the electrical supply voltage and ensure a suitable, correctly rated circuit breaker is available․ Finally, confirm all necessary permits and approvals are obtained before proceeding with the installation process․ Ignoring these checks could compromise safety and boiler performance․

Boiler Mounting and Connections

Securely mount the Ideal Isar HE24 boiler to a stable, level surface, utilizing appropriate fixings suitable for the wall construction․ Ensure sufficient clearance around the boiler for servicing and ventilation, as outlined in the installation guide․ Carefully connect the gas supply pipework, employing gas-tight joints and adhering to all relevant gas safety regulations․

Connect the water pipes, ensuring correct pipework sizing and utilizing appropriate sealing compounds to prevent leaks․ Establish the flue connection, verifying a secure and gas-tight seal․

Finally, connect the electrical supply, ensuring correct wiring and earthing․ Double-check all connections before proceeding to commissioning․

Gas Supply Connection

Crucially, a qualified Gas Safe registered engineer must perform the gas supply connection to the Ideal Isar HE24 boiler․ Verify the gas supply pressure aligns with the boiler’s requirements, detailed in the technical specifications․ Employ appropriately sized gas pipework, adhering to current regulations and standards․

Utilize a gas-tight sealant on all threaded connections, and conduct a thorough leak test using a suitable leak detection fluid after completion․ Install a gas shut-off valve readily accessible for emergency isolation․

Ensure proper ventilation in the boiler room to prevent gas accumulation․ Never attempt to modify or repair gas pipework independently․

Operating Instructions

Familiarize yourself with the Isar HE24’s control panel for effortless operation, temperature adjustments, and system monitoring for optimal heating performance and comfort․

Initial Start-Up and Commissioning

Prior to initial start-up, thoroughly verify all gas and water connections, ensuring they adhere to local regulations and manufacturer specifications․ Confirm the system is adequately pressurized, referencing the ‘Water Pressure Requirements’ section for precise values․

Carefully follow the sequence outlined in the installation guide to purge the gas line, eliminating any trapped air․ Upon gas supply activation, observe the boiler’s ignition sequence․ If ignition fails, immediately shut off the gas supply and consult the ‘Troubleshooting’ section․

Commissioning involves setting the correct heating parameters, including temperature limits and operational modes․ A qualified engineer should perform this step, verifying correct functionality and safety features․ Record all commissioning data for future reference and servicing․

Control Panel Navigation

The Isar HE24’s control panel features a user-friendly interface with intuitive button layouts and a clear digital display․ The ‘Mode’ button cycles through heating options – manual, automatic, and off․ Use the ‘Up’ and ‘Down’ arrows to adjust the desired room temperature, displayed prominently on the screen․

Accessing the settings menu, typically via a prolonged press of the ‘Mode’ button, allows for advanced configuration, including hot water settings and system diagnostics․ Familiarize yourself with the error code display, referencing the ‘Error Code Explanations’ section for troubleshooting․

The ‘Info’ button may display boiler status, gas consumption, and other relevant data․ Always refer to the full manual for a comprehensive understanding of each function and setting․

Temperature Setting and Adjustment

Adjusting the room temperature on your Isar HE24 is straightforward using the ‘Up’ and ‘Down’ arrow buttons on the control panel․ The current setpoint is clearly displayed․ For precise control, consider utilizing the boiler’s programmable timer function, accessible through the settings menu․

Hot water temperature can also be adjusted, typically offering a range from lukewarm to very hot․ Be mindful of Legionella prevention – maintaining a minimum hot water temperature is crucial․

Experiment with settings to find your optimal comfort level, balancing warmth with energy efficiency․ Remember to allow sufficient time for temperature changes to take effect throughout your heating system․

Maintenance and Servicing

Regular upkeep is vital for optimal performance and longevity․ Annual servicing by a qualified engineer is recommended, alongside routine user checks․

Regular Maintenance Tasks

To ensure consistent and efficient operation of your Ideal Isar HE24 boiler, several routine maintenance tasks can be performed by the user․ Regularly visually inspect the boiler for any signs of leaks or corrosion, paying close attention to pipework and connections․ Dust accumulation should be removed from the exterior casing to maintain adequate ventilation․

Check the system pressure monthly, ensuring it remains within the manufacturer’s recommended range – typically between 1 and 1․5 bar․ If pressure is low, repressurise following the instructions in the operating manual․ It’s also advisable to periodically check the flue terminal is unobstructed by debris or snow․ Do not attempt any internal repairs; these should always be carried out by a qualified heating engineer․

Annual Servicing Requirements

A comprehensive annual service, conducted by a Gas Safe registered engineer, is crucial for maintaining the safety and efficiency of your Ideal Isar HE24 boiler․ This service includes a thorough inspection of all gas connections, combustion analysis to ensure optimal burning, and a check of the flue for blockages or corrosion․

The engineer will also examine the heat exchanger for signs of wear and tear, test safety devices, and clean key components․ Crucially, they will verify the carbon monoxide detector is functioning correctly․ Maintaining a service record is vital for warranty purposes and demonstrates responsible boiler ownership․ Ignoring annual servicing can lead to reduced efficiency, increased fuel bills, and potentially dangerous situations․

Fault Finding ⎻ Common Issues

Several common issues can arise with the Ideal Isar HE24 boiler․ A “DRY FIRE THERMISTOR ERROR” (code H․․․․․4․․․․) often indicates a wiring continuity problem, requiring professional inspection – simply resetting the mains power won’t fix it․ Low water pressure is another frequent concern; check radiators are bled and the system pressure is within the recommended range (typically 1-1․5 bar)․

If the boiler isn’t igniting, verify the gas supply is on and there are no airlocks in the gas line․ Always consult a Gas Safe registered engineer for any gas-related concerns․ Attempting self-repair can be dangerous․ Regularly checking error codes and referencing the full installation and servicing guide can aid initial diagnosis, but professional assistance is paramount․

Descaling Procedures

Regular descaling is crucial for maintaining the efficiency of your Ideal Isar HE24 boiler, particularly in hard water areas․ Limescale buildup reduces heat transfer and can lead to component failure․ The frequency of descaling depends on water hardness; annual descaling is generally recommended․

A qualified engineer should perform descaling using a suitable descaling solution, following the manufacturer’s instructions precisely․ Never attempt to descale the boiler yourself․ The process involves circulating the descaling solution through the heat exchanger to dissolve limescale deposits․ After descaling, the system must be thoroughly flushed with clean water to remove any remaining solution․ Proper descaling extends boiler lifespan and optimizes performance․

Safety Information

Prioritize safety! This boiler features crucial safety mechanisms; always adhere to provided guidelines to prevent hazards and ensure proper operation․

Boiler Safety Features

The Ideal Isar HE24 boiler incorporates several key safety features designed to protect both the user and the appliance․ A primary feature is the automatic shutdown system, which activates in response to detected faults like flame failure or excessive temperature․ This prevents potential hazards and damage․

Furthermore, the boiler includes a high-limit thermal switch, safeguarding against overheating․ Regular checks of these features are vital․ The system also boasts frost protection, preventing freezing damage during colder months․ Crucially, proper ventilation is essential for safe operation, ensuring adequate airflow for combustion․ Always ensure the flue is unobstructed and functioning correctly․ Adherence to these safety protocols guarantees reliable and secure performance․

Carbon Monoxide Detection

Crucially, the Ideal Isar HE24 boiler operates using combustion, producing potentially dangerous carbon monoxide (CO)․ Therefore, installing a certified CO detector is mandatory in the same room as the boiler, and in adjacent living spaces․ Ensure the detector meets current safety standards (BS EN 50292)․

Regularly test the CO detector’s functionality – at least monthly – and replace it according to the manufacturer’s instructions (typically every 5-7 years)․ Familiarize yourself with the alarm’s sound and the appropriate emergency procedures․ Never ignore a CO alarm; evacuate immediately and contact emergency services․ Proper boiler maintenance, including annual servicing, minimizes CO risk․ A correctly fitted and maintained flue is also vital for safe exhaust expulsion․

Emergency Procedures

In case of a boiler malfunction, immediately turn off the gas supply at the meter․ Do not attempt self-repair; contact a qualified Gas Safe registered engineer․ If you suspect a gas leak – smell gas, hear a hissing sound, or experience dizziness – evacuate the premises immediately and call the emergency gas helpline․

For a carbon monoxide alarm activation, follow the same evacuation protocol and contact emergency services․ If the boiler is making unusual noises, displaying error codes, or leaking water, switch it off and seek professional assistance․ Keep emergency contact numbers readily available․ Familiarize all household members with these procedures to ensure a swift and safe response․

Technical Specifications

Detailed specifications include the boiler’s dimensions, weight, gas consumption rates, and required water pressure – crucial for optimal performance and installation․

Dimensions and Weight

Understanding the physical characteristics of the Ideal Isar HE24 is vital for proper installation planning and ensuring it fits seamlessly into your designated space․ The boiler’s compact design optimizes installation flexibility within various home environments․

Typically, the Isar HE24 boasts dimensions around 700mm in height, 400mm in width, and 290mm in depth․ These measurements are approximate and should be verified with the official installation manual for precise figures․ Regarding weight, the unit generally weighs approximately 30 kilograms․

This weight consideration is important for safe handling during installation and mounting procedures․ Always ensure the supporting structure is capable of bearing the boiler’s weight securely․ Accurate dimensional and weight data prevents installation issues and guarantees long-term stability․

Gas Consumption Rates

Understanding gas consumption is crucial for estimating running costs and ensuring efficient boiler operation․ The Ideal Isar HE24’s gas consumption varies based on the heating output level selected․ At its maximum output, typically around 24kW, the boiler consumes approximately 2․8 cubic meters of natural gas per hour․

For lower output settings, the consumption rate decreases proportionally․ It’s important to note these figures are estimates and can be influenced by factors like gas supply pressure and flue configuration․

Consult the official Ideal Isar HE24 installation and servicing guide for precise gas consumption data specific to your model and installation․ Regularly monitoring gas usage helps identify potential inefficiencies and optimize boiler performance, leading to cost savings․

Water Pressure Requirements

Maintaining correct water pressure is vital for the Ideal Isar HE24 boiler’s optimal performance and longevity․ The recommended static water pressure for this boiler typically falls between 1․5 and 2․0 bar․ Pressure below 1․0 bar may prevent the boiler from operating correctly, while exceeding 2․5 bar could trigger the pressure relief valve, potentially causing water leakage․

Regularly check the pressure gauge on the boiler’s control panel․ If adjustments are needed, use the filling loop (following the instructions in the full user guide) to increase pressure․

Low pressure often indicates a leak within the heating system, requiring professional attention․ Consistent pressure issues should be addressed by a qualified heating engineer to prevent damage․

Troubleshooting

Facing issues? This section details common problems with your Ideal Isar HE24, offering solutions for ignition failures, low pressure, and error codes․

Boiler Not Igniting

Problem: If your Ideal Isar HE24 fails to ignite, several factors could be at play․ First, verify the gas supply is active and the boiler is receiving gas․ Check if other gas appliances are functioning correctly․ Next, inspect the electrical connections – ensure the boiler is properly powered on and the fuse hasn’t tripped․

Further Checks: A common issue is a faulty ignition electrode or a problem with the flame detection sensor․ These components may require professional inspection and replacement․ Also, check for error codes displayed on the control panel, as these provide valuable diagnostic information․ If the fault condition cannot be reset by switching off the mains supply, professional assistance is crucial․ Do not attempt repairs if you are not a qualified gas engineer․

Low Water Pressure Issues

Problem: Insufficient water pressure can prevent your Ideal Isar HE24 from operating correctly, potentially leading to heating and hot water failures․ First, check the system pressure gauge on the boiler – it should ideally be between 1 and 1․5 bar when cold․ Low pressure may indicate a leak somewhere in the heating system, such as radiators, pipes, or the boiler itself․

Remedial Actions: You can attempt to repressurize the system using the filling loop, following the instructions in the ‘Operating Instructions’ section; However, if the pressure drops repeatedly, a leak must be identified and repaired by a qualified heating engineer․ Ignoring low pressure can cause boiler damage․ Do not overpressurize the system, as this can also cause issues․

Error Code Explanations

Understanding error codes is crucial for diagnosing issues with your Ideal Isar HE24 boiler․ The boiler’s control panel displays codes indicating specific faults․ For example, code 92 (H․․․․․4․․․․) signifies a “Dry Fire Thermistor Error,” meaning the thermistor isn’t detecting flame, and resetting by switching off the mains won’t fix it – wiring continuity needs checking․

Refer to the full error code list in this guide or the official Ideal Heating documentation for a comprehensive explanation of each code․ Some codes may indicate minor issues you can resolve yourself (like low water pressure), while others require a qualified heating engineer․ Never attempt repairs if you are unsure; safety is paramount․ Always note the error code before contacting a technician․